← cyphonix.comSign in to the console
Cyphonix Backup

Home › Documentation › Troubleshooting › Error codes › CBK-2011: Clock skew too large

CBK-2011: Clock skew too large

Code
CBK-2011
Category
Network
Logged as
Error
Applies to
Agent 4.5.0 and later

Message

CBK-2011 Device clock is 00:17:42 behind server time; requests rejected

Cause

Requests from the agent are signed with a timestamp, and the service rejects requests more than five minutes out. This protects against a captured request being replayed later.

Before agent 4.5.0 the same condition was reported as a generic authentication failure, which was harder to diagnose.

Resolution

Correct the device's clock and make sure it stays correct.

The agent retries automatically once the clock is within tolerance.

Last reviewed: · Report a problem with this page