Home › Knowledge base › Clock skew rejects uploads
Clock skew rejects uploads
- Article
- KB-1023
- Category
- Connectivity
- Applies to
- All platforms
Symptoms
Jobs fail immediately. Agent 4.5.0 and later report CBK-2011. Earlier agents report "request signature rejected" or "authentication failed" even though the device is correctly registered.
Cause
The device's clock is more than five minutes from the correct time. The service rejects signed requests outside that tolerance.
The cases we see most often:
- Virtual machines resumed from a saved state or reverted to a checkpoint
- Domain-joined machines where the domain's own time source has drifted
- Devices that have been powered off for months with a flat CMOS battery
- Dual-boot machines where another operating system has changed the hardware clock
- A time zone set incorrectly and the clock then "corrected" by hand to show the right local time
Resolution
Set the clock by synchronising with a time source, not by hand. See the platform steps under CBK-2011.
For a whole domain that has drifted, fix the time source on the domain controller holding the PDC emulator role:
w32tm /config /manualpeerlist:"0.pool.ntp.org 1.pool.ntp.org" /syncfromflags:manual /reliable:yes /update
w32tm /resync
Other machines follow within a few hours, or immediately with w32tm /resync.